According to the excellent penetrability of vapor, the wetting
machine of Chinese Traditional Medicine works in the following
principle; the vapor in low temperature rapidly goes into the inner
of medicinal materials which are in the vacuum and then soften them
in a rapid way .
It is a new type machine for the making and processing of Chinese
Traditional Medicine, making Chinese Traditional Medicine material
penetrated quickly and completely. This can not only preserve
medicinal composition of medicine in most extent, but also improve
the quality of medicinal slices. After vapor wet treating the
medicinal slices are in low water content and are easily dried.
The machine is designed and produced according to the criterion of
pressure vessel. The door of device adopts patent technology, so it
have very good seal performance in the same time can operate in
convenience. The machine can be use for not only wetting Chinese
Traditional Medicine, but also by vapor sterilizing them. It has a
broad application foreground in the making of Chinese Traditional
Medicine materials.
Structure & Capability & Characteristics
The box is designed , produced and tested strictly according to the
《Steel Pressure Vessel》.
Pneumatic translational door, easy to operate, flexible
The unique dove-tail inlaid design of heat-resisting silicone
rubber gasket ring ensures the seal tightness of the door
Reliable and stable micro-computer automatic control PLC + touch
screen control, advanced function for recording,
printing and storing, etc.
Elegant stainless steel decorate cover:
The heat preservation layer is made by polyurethane material and
pearl rock wool
The GMP confirmation access is fixed on the equipment
The special wetting technics can make the medicine wetting rapidly
and efficiently.
Main Parameters and Utilities
| Design Pressure | 0.245Mpa |
| Vacuum | -0.095Mpa |
| Working Pressure | 0.22Mpa |
| Steam Pressure | 0.4-0.6Mpa |
| Design Temperature | 139℃ |
| Water Pressure | 0.1-0.3Mpa |
| Working Temperature | 134℃ |
| Compressed Air Pressure | 0.5-0.7Mpa |
| Heat equilibrium | ≤±1℃ |
Size & Utilities
| Model | Overall Dimensions L*W*H (mm) Single/Double Door | Chamber Size L*W*H(mm) | Steam Consumption (kg/cycle) | Water Consumption (kg/cycle) | Sterilizing Cart | Power (Kw) | Net Weight (kg) Double door |
| ZRJ-0.3 | 1195*1220*1720 | 1000*600*600 | 25 | 200 | non | 1.5 | 760 |
| ZRJ-0.6 | 1245*1300*1880 | 1050*680*850 | 30 | 250 | non | 2.0 | 1100 |
| ZRJ-1.2 | 1695*1370*1960 | 1500*750*1100 | 40 | 350 | 2 | 3.0 | 1900 |
| ZRJ-2.5 | 3195*1370*1960 | 3000*750*1100 | 80 | 600 | 4 | 4.5 | 2800 |
| ZRJ-5.0 | 3635*1800*2200 | 3400*1000*1500 | 170 | 800 | 4 | 7.5 | 4500 |
| ZRJ-8.0 | 5635*1800*2200 | 5400*1000*1500 | 300 | 1000 | 6 | 7.5 | 7500 |